{"title":"Titanium Mesh","description":"","products":[{"product_id":"bionnovation-surgitime-titanium-mesh-non-absorbable-titanium-membrane-34x25-mm-0-85-mm-hole","title":"Surgitime Titanium Mesh - Non Absorbable Titanium Membrane - 34x25 mm - 0,85 mm Hole","description":"\u003cdiv\u003e Titanium mesh has excellent biocompatibility and occlusive property. Because it is permeable, it allows the transmission of nutrients, it is easy to use, as it is very malleable and can be cut to adapt to surgical sites. It has the ability to maintain an intact regenerative space and the possibility of vascularization of the graft on both sides [periosteum and endosseum]. It is designed to ensure the three-dimensional reconstruction of alveolar bone defects and facilitate bone replacement through proper fixation of replacement material.\u003cbr\u003eindications\u003c\/div\u003e\n\u003cdiv\u003eHandlings .\u003c\/div\u003e\n\u003cdiv\u003eSurgitime . titanium (titanium mesh) is indicated for medical (orthopedics and neurosurgery) and dental (periodontics, oral and maxillofacial, implantology) regenerative procedures, mainly for bone reconstruction. The perforations in the mesh allow the diffusion of interstitial fluid, but do not allow the invasion of connective tissue and epithelial cells. Because it has memory, it can be pre-shaped to the defect and fixed with screws for grafting and fixation, but there is no need to use the graft screw for the titanium mesh to perform its function, its use varies according to the choice of the professional who uses it.\u003c\/div\u003e\n\u003cdiv\u003eSurgitime . Titanium must be molded according to the anatomy of the bone and must not be bent at sharp angles, scratched or deformed. Once used and molded, it must not be molded again, as it may result in the failure of the product's function.\u003cbr\u003eAdvantages .\u003c\/div\u003e\n\u003cdiv\u003e. Ease of use in surgical sites [moldability];\u003c\/div\u003e\n\u003cdiv\u003e. No trauma to soft tissues;\u003c\/div\u003e\n\u003cdiv\u003e. Adequate containment of the bone graft;\u003c\/div\u003e\n\u003cdiv\u003e. Improves space for bone regeneration;\u003c\/div\u003e\n\u003cdiv\u003e. Ultra thin[Thickness~0.04 mm and 0.08 mm];\u003c\/div\u003e\n\u003cdiv\u003e. Biocompatible;\u003c\/div\u003e\n\u003cdiv\u003eTitanium meshes are an excellent vehicle for maintaining the dimensions of the desired crest increase.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eThe minimum stay for the start of osteoconduction is at least 21 days.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eAs long as there is no exposure, in cases of ROG the meshes must be removed in the subsequent surgical stage (implantation or reopening). If early exposure occurs, it is recommended that the titanium meshes remain in place for a period of 60 days for their removal.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eOnce exposed, the surgitime . titanium (titanium mesh) prevents a large loss of the graft, as there is an epithelial closure around the mesh.\u003c\/div\u003e\n\u003cdiv\u003eSurgitime Titanium 34 x 25 mm I Thickness 0.04 mm I Hole 0.85 mm\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e","brand":"Bionnovation","offers":[{"title":"Default Title","offer_id":41969677008977,"sku":"BIO.16472","price":75.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/1692\/6545\/files\/surgitime-titanium-mesh-non-absorbable-titanium-membrane-34x25-mm-085-mm-hole-414009.jpg?v=1783691370"},{"product_id":"bionnovation-surgitime-titanium-mesh-non-absorbable-customized-to-the-surgical-mesh-3dl-3-in-1","title":"Surgitime Titanium Mesh - Non-Absorbable customized to the surgical mesh - 3DL 3 in 1","description":"\u003cp\u003e\u003cstrong\u003eIt is very easy to work with surgitime . 3DL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to its flexibility, it can be easily customized to the surgical site\u003cbr\u003e1 . Fixing hole ø 2.5 \u003cbr\u003e2 . Use Implant Cover or Healer to fix the membrane in the desired place.\u003cbr\u003e3 . Thickness: 0.08 mm\u003cbr\u003e4 . The holes measuring ø 0.35 mm prevent displacement or migration of the bone graft material but allow the blood to diffuse into the graft.\u003cbr\u003eBiocompatibility .\u003cbr\u003eBecause it is made of commercially pure titanium, it promotes excellent biological stability, which is beneficial for bone formation. They are made of PURE Titanium Gr 1 [ASTM F-67].\u003cbr\u003eStabilization .\u003cbr\u003eIt has superior resistance to the absorbable membrane and excellent space retention, and can be stabilized directly on the implant with the healer, or using the cover screw of the tent DM screw.\u003cbr\u003eFlexibility .\u003cbr\u003eWith a thickness of 0.08 mm , it can be easily molded into the desired shape. The ø 0.35 mm holes  prevent the displacement of the bone graft, but allow the diffusion of blood in the graft.\u003cbr\u003eCustomized.\u003cbr\u003eCustomized for all types of bone defect allowing molding in 3 different shapes , being Original +  2 customized shapes ( Cutting Guidelines Guide Line)\u003cbr\u003e\u003cstrong\u003eSurgitime Titanium 3DL 12 x18 mm\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Bionnovation","offers":[{"title":"Default Title","offer_id":41969733337169,"sku":"BIO.161261","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/1692\/6545\/files\/surgitime-titanium-mesh-non-absorbable-customized-to-the-surgical-mesh-3dl-3-in-1-339373.jpg?v=1783691369"},{"product_id":"bionnovation-surgitime-titanium-mesh-non-absorbable-titanium-membrane-34x25-mm-0-15-mm-hole","title":"Surgitime Titanium Mesh - Non Absorbable Titanium Membrane - 34x25 mm - 0,15 mm Hole","description":"\u003cdiv\u003e Titanium mesh has excellent biocompatibility and occlusive property. Because it is permeable, it allows the transmission of nutrients, it is easy to use, as it is very malleable and can be cut to adapt to surgical sites. It has the ability to maintain an intact regenerative space and the possibility of vascularization of the graft on both sides [periosteum and endosseum]. It is designed to ensure the three-dimensional reconstruction of alveolar bone defects and facilitate bone replacement through proper fixation of replacement material.\u003cbr\u003eindications\u003c\/div\u003e\n\u003cdiv\u003eHandlings .\u003c\/div\u003e\n\u003cdiv\u003eSurgitime . titanium (titanium mesh) is indicated for medical (orthopedics and neurosurgery) and dental (periodontics, oral and maxillofacial, implantology) regenerative procedures, mainly for bone reconstruction. The perforations in the mesh allow the diffusion of interstitial fluid, but do not allow the invasion of connective tissue and epithelial cells. Because it has memory, it can be pre-shaped to the defect and fixed with screws for grafting and fixation, but there is no need to use the graft screw for the titanium mesh to perform its function, its use varies according to the choice of the professional who uses it.\u003c\/div\u003e\n\u003cdiv\u003eSurgitime . Titanium must be molded according to the anatomy of the bone and must not be bent at sharp angles, scratched or deformed. Once used and molded, it must not be molded again, as it may result in the failure of the product's function.\u003cbr\u003eAdvantages .\u003c\/div\u003e\n\u003cdiv\u003e. Ease of use in surgical sites [moldability];\u003c\/div\u003e\n\u003cdiv\u003e. No trauma to soft tissues;\u003c\/div\u003e\n\u003cdiv\u003e. Adequate containment of the bone graft;\u003c\/div\u003e\n\u003cdiv\u003e. Improves space for bone regeneration;\u003c\/div\u003e\n\u003cdiv\u003e. Ultra thin[Thickness~0.04 mm and 0.08 mm];\u003c\/div\u003e\n\u003cdiv\u003e. Biocompatible;\u003c\/div\u003e\n\u003cdiv\u003eTitanium meshes are an excellent vehicle for maintaining the dimensions of the desired crest increase.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eThe minimum stay for the start of osteoconduction is at least 21 days.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eAs long as there is no exposure, in cases of ROG the meshes must be removed in the subsequent surgical stage (implantation or reopening). If early exposure occurs, it is recommended that the titanium meshes remain in place for a period of 60 days for their removal.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eOnce exposed, the surgitime . titanium (titanium mesh) prevents a large loss of the graft, as there is an epithelial closure around the mesh.\u003c\/div\u003e\n\u003cdiv\u003eSurgitime Titanium 34 x 25 mm I Thickness 0.04 mm I Hole 0.15 mm\u003c\/div\u003e\u003cbr\u003e","brand":"Bionnovation","offers":[{"title":"Default Title","offer_id":41969758601297,"sku":"BIO.16565","price":75.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/1692\/6545\/files\/surgitime-titanium-mesh-non-absorbable-titanium-membrane-34x25-mm-015-mm-hole-357754.jpg?v=1783691367"},{"product_id":"bionnovation-surgitime-titanium-seal-titanium-foil-34x25-mm-non-absorbable-mesh","title":"Surgitime Titanium Seal (Titanium-Foil) 34x25 mm Non- Absorbable Mesh","description":"\u003cp\u003eSurgitime Titanium Seal (Titanium-Foil) is ideal for three- dimensional bone regeneration (GBR, Guided Bone Regeneration). If necessary, it can be attached with pins or screws.\u003c\/p\u003e\n\u003cp\u003eMaterial\u003cbr\u003eTitanium Grade I (ASTM F-67) : Thickness 0.04mm.\u003c\/p\u003e\n\u003cp\u003eSafety\u003cbr\u003eTitanium is a safe material with an excellent history in all the surgical procedures.\u003c\/p\u003e\n\u003cp\u003eHandling Benefits\u003cbr\u003eThe fully impermeable Titanium-Foil is prestressable, stable and acts as a space maker, e.g. for alveolar ridge augmentation. Surgitime Titanium SEAL neutral bioelectrically thanks to electrochemical passivation and thus contribute to an uneventful growth of new bone.\u003c\/p\u003e\n\u003cp\u003eAdvantages: Manipulation\u003cbr\u003eSurgitime Titanium Seal is very flexible and can be used to cover periodontal or alveolar defects and generally does not require fixation, but if necessary, the Bionnovation graft and fixation screw accessory can be used.\u003c\/p\u003e\n\u003cp\u003eSurgical Procedure\u003cbr\u003eThe Titanium Seal is indicated for alveolar sealing procedures, protecting the surgical wound against the invagination of the soft tissues, which promotes resorption of the alveolar process. Therefore, there is a statistically proven decrease of absorption reduction. It should be used through the modeling of the mesh with the careful covering of the operated zone completely with a margin that varies from 2 to 4 mm. It should not be reprocessed and attention must be paid to the sterilization period and correct instrumentations. Regarding the restrictions, the professional is responsible for choosing the implementation site, that is, he must carefully consider its use in the esthetic environment. Due to its color, it may cause some discomfort from the social point of view.\u003cbr\u003eDue to its malleability, it can be cut to adapt to the surgical sites and for being bio-electrically neutral thanks to the electrochemical passivation, it contributes to new bone growth without intercurrences.\u003cbr\u003e\u003cstrong\u003eDimensions\u003cbr\u003e34 x 25 mm \/ 0,04 mm thickness\u003c\/strong\u003e\u003c\/p\u003e","brand":"Bionnovation","offers":[{"title":"Default Title","offer_id":41969758994513,"sku":"BIO.16890","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/1692\/6545\/files\/surgitime-titanium-seal-titanium-foil-34x25-mm-non-absorbable-mesh-784618.jpg?v=1733213834"},{"product_id":"bionnovation-surgitime-titanium-mesh-non-absorbable-customized-to-the-surgical-mesh-3df-3-in-1","title":"Surgitime Titanium Mesh - Non-Absorbable customized to the surgical mesh - 3DF 3 in 1","description":"\u003cp\u003e\u003cstrong\u003eIt is very easy to work with surgitime . 3DF\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to its flexibility, it can be easily customized to the surgical site\u003cbr\u003e1 . Fixing hole ø 2.5 \u003cbr\u003e2 . Use Implant Cover or Healer to fix the membrane in the desired place.\u003cbr\u003e3 . Thickness: 0.08 mm\u003cbr\u003e4 . The holes measuring ø 0.35 mm prevent displacement or migration of the bone graft material but allow the blood to diffuse into the graft.\u003cbr\u003eBiocompatibility .\u003cbr\u003eBecause it is made of commercially pure titanium, it promotes excellent biological stability, which is beneficial for bone formation. They are made of PURE Titanium Gr 1 [ASTM F-67].\u003cbr\u003eStabilization .\u003cbr\u003eIt has superior resistance to the absorbable membrane and excellent space retention, and can be stabilized directly on the implant with the healer, or using the cover screw of the tent DM screw.\u003cbr\u003eFlexibility .\u003cbr\u003eWith a thickness of 0.08 mm , it can be easily molded into the desired shape. The ø 0.35 mm holes  prevent the displacement of the bone graft, but allow the diffusion of blood in the graft.\u003cbr\u003eCustomized.\u003cbr\u003eCustomized for all types of bone defect allowing molding in 3 different shapes , being Original +  2 customized shapes ( Cutting Guidelines Guide Line)\u003cbr\u003e\u003cstrong\u003eSurgitime Titanium 3DF 12 x18 mm\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Bionnovation","offers":[{"title":"Default Title","offer_id":41969759223889,"sku":"BIO.161256","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/1692\/6545\/files\/surgitime-titanium-mesh-non-absorbable-customized-to-the-surgical-mesh-3df-3-in-1-527415.jpg?v=1783691369"}],"url":"https:\/\/boboth.co\/collections\/titanium-mesh.oembed","provider":"Boboth","version":"1.0","type":"link"}